Monday, March 25, 2013
Planting Season
Euonymus Silver King
Planted 10 Euonymus Silver King Shrubs along my front fence. They should grow fast to 4-6 feet wide and tall.
Wednesday, March 20, 2013
Daphne's Room Gets Painted
From a blah white room to a primary palace! Bought 1 gallon of each color. Used up almost all the yellow.
Tuesday, March 19, 2013
Tuesday, January 29, 2013
Building Buildings?
Just playing with the aerial shot of my property and laid out a casita along with a 500 SQFT garage and driveway that could be built to my fence line. Just something to keep in mind for the future.
Red = 1000 SQFT house
Purple = 500 SQFT Garage
Green = 20 Foot Driveway
Monday, January 28, 2013
R60 Attic Update #1
After getting two quotes at $2100 and $3000 for R48 attic insulation only, I decided to let EnergyPro do my attic at R60 for $2175. Additionally they leak tested my house, leak tested my ductwork, installed weather stripping at 3 doors, insulated all my wall outlets, and spot seal my attic; canned lighting; ductwork & plenums.
All in all, I think it was a good deal. Turns out I had a wide open vent at my kitchen hood vent. I plan to replace the entire hood and install an internal damper. Currently I have removed the fan and just taped off the open 8" duct. This duct was responsible for the previous posts super high CFM in the leak test.
This new test I believe is more accurate result of my "loose" house which really was not that bad. This tested value was 2400 CFM @ 50 Pascals. Not too far from an Energy Star compliant home! We shall see if I get there after all sealing is complete.
Both my heat pumps were leak tested at a 25 Pascals and found to be leaking at around 250CFM each which when divided by their 4 Tonnage size results in the calculated loss of about 14% (anything over 20% is considered faulty)
For more details:
http://en.wikipedia.org/wiki/Duct_leakage_testing

Bedroom Unit: 224 CFM@25Pascals / 1600 = 14% leakage
Kitchen Unit: 214 CFM@25Pascals /1600 = 13.4% leakage
Sealed up many openings in attic and all around the chimney:

Filled up the attic with CertainTEED blown fiberglass to a height of 22 inches getting a maximum of R60.
All in all, I think it was a good deal. Turns out I had a wide open vent at my kitchen hood vent. I plan to replace the entire hood and install an internal damper. Currently I have removed the fan and just taped off the open 8" duct. This duct was responsible for the previous posts super high CFM in the leak test.
This new test I believe is more accurate result of my "loose" house which really was not that bad. This tested value was 2400 CFM @ 50 Pascals. Not too far from an Energy Star compliant home! We shall see if I get there after all sealing is complete.
Both my heat pumps were leak tested at a 25 Pascals and found to be leaking at around 250CFM each which when divided by their 4 Tonnage size results in the calculated loss of about 14% (anything over 20% is considered faulty)
For more details:
http://en.wikipedia.org/wiki/Duct_leakage_testing
Bedroom Unit: 224 CFM@25Pascals / 1600 = 14% leakage
Kitchen Unit: 214 CFM@25Pascals /1600 = 13.4% leakage
Sealed up many openings in attic and all around the chimney:
12 Canned Lights Throughout House
Chimney Perimeter Had Clear Openings to Living Room
Although Not Energy Improvement, Possible Leaks Prevented At Roof Openings
Bathroom Fans Too
Filled up the attic with CertainTEED blown fiberglass to a height of 22 inches getting a maximum of R60.
Filling In Around Chimney Area - Voids of Chimney Sides Also Filled In.
The workers said this was a really big house and they used 6 cans of foam sealant when they normally use 1 or 2. They worked until about 8pm and had to close up before finishing. They will need to come back to "pooky" seal up the rooftop AC plenums and perform their final pressure tests to verify the sealing improvement to the house and ducts.
Truck Pumping Fiberglass
Friday, January 18, 2013
Attic Work
Started getting my house checked out by Energy Pro's who tell me I can get a $3000 rebate of weatherizing my house. They performed a blower door test creating a pressure differential of 50 pascals which required 6000 CFM of air to maintain. That's a pretty leaky house. We will be reducing this leakage by sealing openings around the ceiling at the chimney and canned lights.
So at Q=6000 CFM @ 50 Pascals, this puts my ACH@50 (Air Changes per hour @ 50 pascals) equal to 15.1 for my 3100 sqft house (about 23,800 interior cubic feet).
My ACHnatural (natural air changes per hour) = ACH@50/20 = 0.756 changes per hour. A tight house should be at 0.4-0.5
My house ACH@50 = 15.1
Energy Star 2.0 requires ACH@50 < 5
Energy Star 2.5 requires ACH@50 < 4
PassivHaus requires ACH@50 < 0.6
So in order to obtain the "good" energy rating for my house tightness, I need to reduce leakage down to the following to meet said standards.
Energy Star 2.0 < 1983 CFM @ 50 Pascals
Energy Star 2.5 & 3.0 < 1586 CFM @ 50 Pascals
PassivHaus < 238 CFM @ 50 Pascals (not gonna happen)
So at Q=6000 CFM @ 50 Pascals, this puts my ACH@50 (Air Changes per hour @ 50 pascals) equal to 15.1 for my 3100 sqft house (about 23,800 interior cubic feet).
My ACHnatural (natural air changes per hour) = ACH@50/20 = 0.756 changes per hour. A tight house should be at 0.4-0.5
My house ACH@50 = 15.1
Energy Star 2.0 requires ACH@50 < 5
Energy Star 2.5 requires ACH@50 < 4
PassivHaus requires ACH@50 < 0.6
So in order to obtain the "good" energy rating for my house tightness, I need to reduce leakage down to the following to meet said standards.
Energy Star 2.0 < 1983 CFM @ 50 Pascals
Energy Star 2.5 & 3.0 < 1586 CFM @ 50 Pascals
PassivHaus < 238 CFM @ 50 Pascals (not gonna happen)
Door Blow Test 1/16/2013
While they were in the attic they discovered potentially unsafe wire conditions with connections made outside of J-boxes. Yesterday I hired an electrician to install J-boxes at all exposed connection points. This was due to the removal of the utility room and transfer of the water heater to the outside back side patio.
New Water Heater J-box
J-boxes installed over new extra room in-place of old Utility room.
J-boxes installed over office area
Another New Rear Tire on Bike
At 8400 miles I've replaced another tire on my bike. Brand new Metzler Marathon bought at below website and had them price match a competitor at $261.64
http://www.directlineparts.com
http://www.directlineparts.com/product.asp?pid=5212&str=290&mdl=&mdy=
http://www.directlineparts.com
http://www.directlineparts.com/product.asp?pid=5212&str=290&mdl=&mdy=
Old tire had worn on left side to show steel bands.
Monday, January 07, 2013
Tuesday, January 01, 2013
Tuesday, December 11, 2012
Induction Cook'n!
Replaced the nasty inefficient old cooktop I had in my new house with this sleek new induction cooktop from GE. This is the big 36" PHP960DM2BB So far all but our cast iron cookware are non-ferrous so they dont work. We did test out boiling some water in a thick cast iron skillet. It took about 3 seconds to boil up a thin layer of water with that thing. Also was able to put a paper towel under the pot (to stop any scratching) and put my hand right on the burner after lifting up the pot. Best thing about this is that I got it off Craigslist for $500!
Out with the old 1976 resistance coil oven. Craiglisted this and sold it for $20
Thursday, October 25, 2012
Sink Upgrade
Before shot, unfortunately dont have a b4 shot of the faucet, it was ugly, leaky and calcified. Below was nasty with a rotted out garbage disposal that flung its contents around underneath. Old funky routed piping.
Everything was replaced other than the actual 4 hole sink. Not sure what to do with the last hole, but thinking putting a lotion dispenser. New disposal is a 1 hp Waste King, much quieter.
Total Cost was a couple trips to home depot for $40 worth of pipes, drains, floorboard and $245 on Amazon for the Faucet and 1 hp disposal.
Faucet
Disposal
Disposal Button
Before shot, unfortunately dont have a b4 shot of the faucet, it was ugly, leaky and calcified. Below was nasty with a rotted out garbage disposal that flung its contents around underneath. Old funky routed piping.
Everything was replaced other than the actual 4 hole sink. Not sure what to do with the last hole, but thinking putting a lotion dispenser. New disposal is a 1 hp Waste King, much quieter.
Total Cost was a couple trips to home depot for $40 worth of pipes, drains, floorboard and $245 on Amazon for the Faucet and 1 hp disposal.
Faucet
Disposal
Disposal Button
Monday, October 15, 2012
Daphne in Disney 40+ Inches Tall
Daphne had her first experience in Disney and California Adventure being over 40 inches tall. Got to go on lots of new rides. She handled all the coasters like a champ. No fear.
Tuesday, February 21, 2012
Monday, December 05, 2011
Saturday, October 29, 2011
Monday, October 24, 2011
Saturday, September 10, 2011
Friday, September 09, 2011